Not sure where to start? Send us the number of rooms, devices or access points – we will propose a package.

Power that keeps servers, network and data intact

UPS sized by the real consumption of your equipment: servers and the network keep running until the generator starts or the system shuts down cleanly – data stays intact and hardware unharmed.

Rows of server racks in a data centre with blue lighting
  • Sized by real consumption, not catalogue figures
  • Online (double-conversion) and rack models
  • Monitoring, PDU and generator coordination

Who it is for

For companies where a power cut is not an option

A power outage must not be an incident: servers have to shut down cleanly, the network has to keep running and data has to stay intact.

Servers and racks

A UPS for the server rack: enough time for a clean shutdown or running until the generator takes over.

Network and internet

Switches, routers and the internet link stay alive – so the network does not go down before the servers.

Multiple sites

The same power standard at every address, with a central view of the status.

Monitoring and reports

Power monitoring over the network: battery status, consumption and alarms before problems hit.

Works with the environment you already use

Servers and network equipment Any ISP and generator Network monitoring (SNMP) APC, Legrand, CyberPower

What is in the kit

What is in the kit

A UPS chosen by the numbers, mounted and connected to monitoring – not a box out of a catalogue.

Equipment

A UPS sized to the load, plus rack accessories.

  • Online (double-conversion) or line-interactive UPS
  • Rack or tower form factor, PDU distribution
  • Additional battery modules as needed

Manufacturer software

Monitoring and clean shutdown.

  • Agents for graceful server shutdown
  • SNMP monitoring and alarms
  • Consumption and battery reports

Work at your request

Installation, test and configuration.

  • Rack mounting and wiring
  • A power-cut test with your team
  • Shutdown rules and alarm configuration

UPS catalog

Models on offer – APC, Legrand and CyberPower

Enterprise and rack models of current generations – every card goes straight to inquiry, with sizing based on real consumption.

Brand:
APC Smart-UPS On-Line SRT1000XLI – 1 kVA tower UPS

APC

APC Smart-UPS On-Line SRT 1 kVA

Tower online UPS za manje servere i mrežne ormare

  • 1 kVA / 1 kW, online double-conversion sa nulom prekidnog vremena
  • 6× C13 IEC izvoda, čist sinusoidni izlaz 230 V
  • Autonomija se proširuje spoljnim baterijskim paketima

Konverzija u rack izvedbu moguća uz set za šine.

Tower1 kVAOnline
APC Smart-UPS On-Line SRT3000XLI – 3 kVA tower UPS

APC

APC Smart-UPS On-Line SRT 3 kVA

Tower online UPS za server ormariće i kritičnu mrežu

  • 3 kVA / 2,7 kW, online double-conversion sa nulom prekidnog vremena
  • 8× C13 + 2× C19 IEC izvoda, čist sinusoidni izlaz 230 V
  • SmartSlot za mrežnu karticu i proširenje autonomije baterijskim paketima

Najtraženiji kapacitet serije – dimenzionisanje radimo po stvarnoj potrošnji.

Tower3 kVA10 izvoda
APC Smart-UPS On-Line SRT3000RMXLI – 3 kVA rack UPS 2U

APC

APC Smart-UPS On-Line SRT 3 kVA Rack

Rack online UPS 2U za server i mrežne ormare

  • 3 kVA / 2,7 kW, online double-conversion sa nulom prekidnog vremena
  • 8× C13 + 2× C19 izvoda, set za šine u paketu
  • Rotirajući LCD panel – čitljiv i iz rack ormara

Isti kapacitet kao tower model, za 2U u rack ormariću.

2U3 kVASet za šine
APC Smart-UPS On-Line SRT5KRMXLI – 5 kVA rack UPS 3U

APC

APC Smart-UPS On-Line SRT 5 kVA Rack

Rack online UPS 3U za server sobe

  • 5 kVA / 4,5 kW, online double-conversion sa nulom prekidnog vremena
  • 6× C13 + 4× C19 izvoda, mrežna kartica u paketu
  • Spoljni baterijski paketi 192 V za dužu autonomiju

Mrežni nadzor odmah po uvođenju – kartica ide u SmartSlot.

3U5 kVAMrežna kartica
APC Smart-UPS On-Line SRT6KRMXLI – 6 kVA rack UPS 4U

APC

APC Smart-UPS On-Line SRT 6 kVA Rack

Rack online UPS 4U za server sobe

  • 6 kVA / 6 kW (faktor snage 1,0), online double-conversion
  • 6× C13 + 4× C19 izvoda, mrežna kartica u paketu
  • Spoljni baterijski paketi 192 V za dužu autonomiju

Puna aktivna snaga bez deratinga – za gušće rack ormare.

4U6 kVAMrežna kartica
APC Smart-UPS On-Line SRT8KXLI – 8 kVA tower UPS

APC

APC Smart-UPS On-Line SRT 8 kVA

Tower online UPS za veće server sobe

  • 8 kVA / 8 kW, online double-conversion sa nulom prekidnog vremena
  • 6× C13 + 4× C19 izvoda, priključak 230/400 V
  • Mrežna kartica u paketu, autonomija kroz baterijske ormare

Kada jedan uređaj nosi ceo server ormarić.

Tower8 kVA230/400 V
APC Smart-UPS On-Line SRT10KRMXLI – 10 kVA rack UPS

APC

APC Smart-UPS On-Line SRT 10 kVA

Rack online UPS za server i mrežne ormare

  • 10 kVA / 10 kW, online double-conversion (VFI) sa nulom prekidnog vremena
  • 6U rack izvedba 230/400 V sa mrežnom karticom
  • Autonomija se proširuje dodatnim baterijskim ormarom

Proveren izbor za server sobe gde gašenje nije opcija.

6U10 kVAOnline
APC Smart-UPS Ultra SRTL5KRM2UI – online rack/tower UPS sa litijum-jonskim baterijama

APC

APC Smart-UPS Ultra 5 kVA

Rack/tower online UPS sa litijum-jonskim baterijama

  • 5 kVA / 5 kW, online double-conversion sa čistim sinusoidnim izlazom
  • Li-ion baterije – 2–3× duži vek i ređe zamene tokom veka uređaja
  • SmartConnect cloud nadzor i mrežna kartica u paketu

Kompaktna 2U izvedba za server ormariće i edge lokacije.

2ULi-ion5 kVA
CyberPower Smart App Online OL6KRT – 6 kVA rack/tower UPS

CyberPower

CyberPower Smart App Online OL6KRT

Rack/tower online UPS za mrežne i server ormare

  • 6 kVA / 5,4 kW, online double-conversion
  • Rack/tower 6U izvedba sa LCD panelom i merenjima potrošnje
  • SNMP/HTTP nadzor opciono kroz RMCARD modul

Online zaštita u nižem budžetu – bez kompromisa po topologiji.

6U6 kVAOnline
CyberPower Smart App Online OL10KRT – 10 kVA rack/tower UPS

CyberPower

CyberPower Smart App Online OL10KRT

Online UPS za ozbiljnije opterećenje u rack formatu

  • 10 kVA / 10 kW, nula vremena prenosa na baterije
  • Čist sinusoidni izlaz 200–240 V za osetljivu opremu
  • Rack/tower 6U, autonomija kroz eksterne baterijske module

Isti rack format, veća nazivna snaga od OL6KRT.

6U10 kVAOnline
Legrand Keor Compact – trofazni online UPS 10–20 kVA

Legrand

Legrand Keor Compact

Trofazni online UPS za manje server prostorije

  • 10–20 kVA trofazni, online double-conversion
  • Kompaktna izvedba za tehničke prostorije bez posebnog prostora za UPS
  • Rad sa eksternim baterijskim ormarima za dužu autonomiju

Kada mreža i serveri idu na trofazno napajanje.

Trofazni10–20 kVA
Legrand Keor HPE – trofazni UPS 60–600 kVA za server sobe i data centre

Legrand

Legrand Keor HPE

Trofazni UPS za server sobe i manje data centre

  • 60–600 kVA, 3-Level IGBT tehnologija visoke frekvencije
  • Efikasnost do 96% u online režimu
  • Paralelni rad N+X do 6 jedinica za redundansu

Skalabilna zaštita koja prati rast server sobe.

60–600 kVAN+X
APC Galaxy VXL – modularni UPS 500–1250 kW za AI podatkovne centre

APC

APC Galaxy VXL

Modularni UPS za AI i visokodenzitetne podatkovne centre

  • 500–1250 kW po sistemu, paralelno do 5 MW
  • Efikasnost do 97,5% uz double-conversion
  • Najveća gustina snage u klasi – 1.042 kW/m² na 1,2 m²

Dizajniran za AI radna opterećenja i kolokacije.

Za AIModularni500 kW+
Legrand Keor FLEX – modularni UPS za AI i HPC opterećenja

Legrand

Legrand Keor FLEX

Modularni UPS za AI i HPC opterećenja

  • Modularna arhitektura sa zamenskim modulima u radu
  • Efikasnost do 98,6% uz visoku dostupnost
  • Skalabilnost po fazama – bez zamene celog sistema

Za dinamička opterećenja AI i HPC klastera.

Za AIModularni98,6%

Not sure which UPS you need?

Describe the equipment the UPS has to carry – we will calculate the consumption and propose a model, runtime and redundancy.

What is useful to tell us

  • What must keep running when the power goes, and for how long
  • Total consumption of the equipment the UPS carries
  • Whether a generator exists and how the switchover works
We will contact you to confirm your requirements.

Runtime, battery cabinets and PDU distribution are selected in the specification – based on the real equipment load.

Packages

Start, Business and Enterprise – by equipment criticality

What has to keep running during an outage determines the size of the UPS – not the floor area.

Start

Server rack / smaller office

Basic protection for servers and the network.

  • Rack UPS for the server and switch
  • Graceful server shutdown on alarm
  • Installation and test – at your request

Enterprise

Whole-facility power

Generator and phase coordination.

  • Three-phase online UPS
  • Generator coordination with automatic transfer
  • Maintenance plan and priority support

Delivery across Serbia

Specify the delivery location and whether installation and commissioning are needed.

Payment terms

Payment and delivery terms are specified in the quote.

A quote for your project

Send the configuration, quantity and requirements so we can prepare a quote.

FAQ

Frequently asked questions

First decide whether the UPS must allow a clean shutdown or bridge the time until a generator starts. Runtime is calculated from the actual load in watts and the manufacturer’s runtime curve for the selected model and batteries. Temperature, battery age and additional equipment affect the result, so suitable headroom is needed.
An online double-conversion UPS is often suitable for sensitive servers and networking. Battery transfer is uninterrupted in double-conversion mode, but ECO or bypass operation can behave differently. Line-interactive units may suit less critical equipment. Selection depends on the load and acceptable interruption.
VA is the apparent-power rating and W is the active-power rating. The load must stay within both limits. A 3 kVA label does not mean every model supplies 3 kW. Runtime is a separate figure determined by the load and batteries, not by the VA rating alone.
Use the supported manufacturer software and, where applicable, an SNMP network card. The card is not included with every model, so it is checked in the specification. Status, load and alarms should be monitored alongside periodic battery checks. Alerts do not replace runtime testing and a replacement plan.
Yes – we coordinate the transfer to the generator, the UPS runtimes and a clean shutdown if the generator is late.

Request a kit specification

Tell us what has to keep running when the power goes and for how long – we will come back with sizing and models.

We will contact you to confirm your requirements.
The quote sets out the configuration, quantities and terms.

A power cut must not stop the job?

Send us your equipment list – we will calculate the consumption and propose a UPS and redundancy to match.

Example of a delivered configuration

Request a demonstration

Leave your contact details to discuss a system demonstration.

Request a quote

Tell us about your requirements for a quote.